6-8
n57
Stall Prevention during Operation
Changes during
operation
No
Setting
range
30 to 200 (%)
Unit of
setting
1%
Default setting
160
Set Values
•
This function will decrease the output frequency if the output current exceeds the set
current value by a minimum of approximately 100 ms so that the Inverter will continue
operating without stalling. The Inverter will increase the output frequency to return to
the set frequency reference level when the output current is less than the set value.
•
The Inverter accelerates or decelerates the output frequency according to the preset
acceleration or deceleration time. (Acceleration time 1: n16, n17 or acceleration time
2: n18, n19)
•
Set the parameter as percentage based on the rated Inverter current as 100%.
•
The default setting does not need any changes in normal operation.
•
Decrease the set value if the capacity of the motor is smaller than that of the Inverter or
the motor stalls with the default value.
The set value is normally 2 or 3 times higher than the rated current of the motor. Set this
current in percentage based on the rated Inverter current as 100%.
Stall Prevention during Acceleration
Output
current
n57 (Stall prevention
level during acceleration)
Time
Output
frequency
The output frequency is controlled
so that the Inverter will not stall.
Time
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3JV-AB001
Page 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Page 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Page 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 62: ...4 10 Test Run Chapter 4...
Page 131: ...7 22 Maintenance Operations Chapter 7...
Page 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Page 138: ...Chapter 9 List of Parameters 9...
Page 150: ...Chapter 10 Using the Inverter for a Motor 10...
Page 165: ...Revision History 10 2...
Page 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...