4-9
•
After changing the frequency reference or the rotation direction, check that there is no
vibration or abnormal sound from the motor.
•
Check that no faults have occurred in the Inverter during operation.
H
Stopping the Motor
•
On completion of operating the motor in the no-load state in the forward or reverse
direction, press the STOP/RESET Key. The motor will stop.
6
Actual Load Operation
•
After checking the operation with the motor in no-load status, connect the mechanical
system and operate with an actual load.
Note Before operating the Digital Operator, check that the FREQ adjuster is set to MIN.
H
Connecting the System
•
After confirming that the motor has stopped completely, connect the mechanical sys-
tem.
•
Be sure to tighten all the screws when fixing the motor axis in the mechanical system.
H
Operation Using the Digital Operator
•
In case a fault occurs during operation, make sure the Stop Key on the Digital Operator
is easily accessible.
•
Use the Digital Operator in the same way as no-load operation.
•
First set the frequency reference to a low speed of one tenth the normal operating
speed.
H
Checking the Operating Status
•
Having checked that the operating direction is correct and that the machine is operat-
ing smoothly at slow speed, increase the frequency reference.
•
After changing the frequency reference or the rotation direction, check that there is no
vibration or abnormal sound from the motor. Check the monitor display (IOUT or multi-
function monitor U03) to ensure that the output current is not becoming excessive.
Test Run
Chapter 4
Summary of Contents for SYSDRIVE 3G3JV-AB001
Page 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Page 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Page 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 62: ...4 10 Test Run Chapter 4...
Page 131: ...7 22 Maintenance Operations Chapter 7...
Page 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Page 138: ...Chapter 9 List of Parameters 9...
Page 150: ...Chapter 10 Using the Inverter for a Motor 10...
Page 165: ...Revision History 10 2...
Page 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...