![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3jv-ab001/sysdrive-3g3jv-ab001_user-manual_742834083.webp)
5-21
Value
Description
Function
17
Local or remote
selection
ON: Local mode (operated with the Digital Operator)
Note After this setting is made, mode selection with the
Digital Operator is not possible.
19
Emergency stop fault
(NO)
The Inverter stops according to the setting in n04 for
interruption mode selection with the emergency stop
input turned ON.
20
Emergency stop
alarm (NO)
input turned ON.
n04 set to 0: Decelerates to stop at deceleration time
2 set in n19. n04 set to 1: Coasts to a stop.
Note NO: Emergency stop with the contact closed.
21
Emergency stop fault
(NC)
Note NO: Emergency stop with the contact closed.
NC: Emergency stop with the contact opened.
Note Fault: Fault output is ON and reset with RESET in-
put Alarm output is ON (no reset required)
22
Emergency stop
alarm (NC)
put. Alarm output is ON (no reset required).
Note “STP” is displayed (lit with fault input ON and
flashes with alarm input ON)
34
Up or down
command
Up or down command (set in n39 only)
By setting n39 to 34, the set value in n38 is ignored and
the following settings are forcibly made.
S4: Up command
S5: Down command
Note It is impossible to set the up or down command and
multi-step speed references 1 through 3 together.
Note For up and down command functions in detail, re-
6-7-7 UP/DOWN Command Frequency
Memory (n62).
H
Operation in 2-wire Sequence (Set Value: 2)
•
The Inverter operates in 2-wire sequence by setting a multi-function input parameter to
2 (reverse/stop).
•
The following diagram shows a wiring example of the terminals in 2-wire sequence.
Forward-rotation
switch
Reverse-rotation
switch
Forward/Stop (Forward rotation with the forward-rotation switch
closed and reverse-rotation switch opened)
Reverse/Stop (Reverse rotation with the reverse-rotation switch
closed and forward-rotation switch opened)
Sequence input common
j
: 2 to 5
Basic Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3JV-AB001
Page 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Page 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Page 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 62: ...4 10 Test Run Chapter 4...
Page 131: ...7 22 Maintenance Operations Chapter 7...
Page 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Page 138: ...Chapter 9 List of Parameters 9...
Page 150: ...Chapter 10 Using the Inverter for a Motor 10...
Page 165: ...Revision History 10 2...
Page 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...