9-11
Pa-
rame-
ter
No.
Refer-
ence
page
Changes
during
opera-
tion
Default
setting
Unit
of set-
ting
Set-
ting
range
Description
Name
n62
UP/DOWN
command
frequency
memory
Used to store the adjusted frequency
reference with the UP/DOWN function.
0: Frequency not stored
1: Frequency stored
The frequency must be on hold for 5 s
or more.
0, 1
1
0
No
n63
Torque
compensation
gain
Used to set the gain of the torque
compensation function.
The default setting does not need any
changes in normal operation.
0.0 to
2.5
0.1
1.0
Yes
6-11
n64
Motor rated slip
Used to set the rated slip value of the
motor in use.
Note
Used as the constant of the slip com-
pensation function.
0.0 to
20.0
0.1 Hz
Varies
with
the ca-
pacity.
Yes
n65
Motor no-load
current
Used to set the no-load current of the
motor in use based on the rated motor
current as 100%.
Note
Used as the constant of the slip com-
pensation function.
0 to 99
1%
Varies
with
the ca-
pacity.
No
n66
Slip
compensation
gain
Used to set the gain of the slip
compensation function.
Note
The slip compensation function is
disabled with n66 set to 0.0.
0.0 to
2.5
0.1
0.0
Yes
n67
Slip
compensation
time constant
Used for the response speed of the slip
compensation function.
Note
The default setting does not need
any changes in normal operation.
0.0 to
25.5
0.1 s
2.0
No
n68
OMRON’s control
reference use
Do not change the set value.
---
---
0
---
---
n69
OMRON’s control
reference use
Do not change the set value.
---
---
0
---
---
n70
OMRON’s control
reference use
Do not change the set value.
---
---
0
---
---
n71
OMRON’s control
reference use
Do not change the set value.
---
---
2
---
---
n72
OMRON’s control
reference use
Do not change the set value.
---
---
0
---
---
n73
OMRON’s control
reference use
Do not change the set value.
---
---
10
---
---
n74
OMRON’s control
reference use
Do not change the set value.
---
---
0
---
---
n75
Low-speed
carrier frequency
reduction
selection
Used to select a function to reduce the
carrier frequency when Inverter is at low
speed.
0: Function disabled
1: Function enabled
Note
Normally set n75 to 0.
0.1
1
0
No
n76
OMRON’s control
reference use
Do not change the set value
---
---
rdy
---
---
n77
OMRON’s control
reference use
Do not change the set value
---
---
0
---
---
List of Parameters
Chapter 9
Summary of Contents for SYSDRIVE 3G3JV-AB001
Page 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Page 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Page 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 62: ...4 10 Test Run Chapter 4...
Page 131: ...7 22 Maintenance Operations Chapter 7...
Page 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Page 138: ...Chapter 9 List of Parameters 9...
Page 150: ...Chapter 10 Using the Inverter for a Motor 10...
Page 165: ...Revision History 10 2...
Page 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...