![background image](http://html1.mh-extra.com/html/omron/nx-ecc201/nx-ecc201_user-manual_742778191.webp)
9 - 21
9 Setting Up Slave Terminals
NX-series EtherCAT Coupler Unit User’s Manual (W519)
9-
2 Sett
ing
Slave T
er
m
inal
P
a
ra
m
ete
rs
9
9-2-4 I/O Allocation
Information
2
Select the option button next to the I/O entry mapping that you wish to edit. You can select only
I/O entry mappings that have the “Editable” in the
Flag
column.
I/O Entry Map-
ping List
This is a mapping list of the I/O entries in the corresponding Unit.
The I/O entry mapping list shows up to four inputs and outputs respectively.
The I/O entry mapping list shows the following items.
• Selection: This column is used to select the I/O entry mappings that you wish to
allocate.
Select the I/O entry mapping that you wish to allocate.
If you do not want to allocate the I/O entry mapping as part of the I/O allocation
information, select
No option
.
• Input/Output: This column shows whether the data is an input or an output in
terms of the CPU Unit.
• I/O entry mapping name: This column gives the name of the I/O entry mapping.
• Flag: If the I/O entry is editable, this column says “Editable.”
If the I/O entry is not editable, this column says “---.”
I/O entries
This pane allows you to view and edit the I/O entries for the I/O entry mappings that
are selected in the I/O Entry Mapping List.
Each I/O entry contains the following information.
• Index:
This is the index number for the NX object.
The index is displayed after “0x” as
index_number:subindex_number.
• Size:
This column gives the size of the I/O entry data.
• Data Type:
This column gives the data type of the I/O entry.
• I/O entry name: This column gives the name of the I/O entry.
• Comment:
This column gives a description of the I/O entry.
Control buttons
for the Edit I/O
Allocation Set-
tings Window
Add I/O Entry
Button:
This button adds an I/O entry to the selected I/O entry
mapping.
Delete I/O Entry
Button:
This button deletes the selected I/O entry from the
selected I/O entry mapping.
OK
Button:
This button confirms the settings in the Edit I/O Alloca-
tion Settings Window, and returns the display to the Edit
Slave Terminal Configuration Tab Page.
Cancel
Button:
This button cancels the settings in the Edit I/O Allocation
Settings Window, and returns the display to the Edit
Slave Terminal Configuration Tab Page.
Apply
Button:
This button confirms the settings in the Edit I/O Alloca-
tion Settings Window, and allows you to edit other I/O
entries.
Name/Label
Description
Summary of Contents for NX-ECC201
Page 38: ...Sections in this Manual 36 NX series EtherCAT Coupler Unit User s Manual W519...
Page 46: ...1 EtherCAT Networks 1 8 NX series EtherCAT Coupler Unit User s Manual W519...
Page 56: ...2 Features and System Configuration 2 10 NX series EtherCAT Coupler Unit User s Manual W519...
Page 82: ...4 Part Names and Functions 4 14 NX series EtherCAT Coupler Unit User s Manual W519...
Page 100: ...5 Designing the Power Supply System 5 18 NX series EtherCAT Coupler Unit User s Manual W519...
Page 214: ...9 Setting Up Slave Terminals 9 44 NX series EtherCAT Coupler Unit User s Manual W519...
Page 254: ...11 EtherCAT Coupler Unit Functions 11 30 NX series EtherCAT Coupler Unit User s Manual W519...
Page 278: ...12 Communications Performance 12 24 NX series EtherCAT Coupler Unit User s Manual W519...
Page 340: ...14 Maintenance and Inspection 14 8 NX series EtherCAT Coupler Unit User s Manual W519...
Page 400: ...Appendices A 60 NX series EtherCAT Coupler Unit User s Manual W519...
Page 401: ...Index 1 NX series EtherCAT Coupler Unit User s Manual W519 I Index...
Page 405: ......