The Sysmac Studio also supports the ability to transfer only the Unit operation settings for a EtherCAT
Coupler Unit or NX Unit in the EtherCAT Slave Terminal. You can use this function when you need to
send only Unit operation settings.
Use the following procedures to transfer only the Unit operation settings.
1
Place the Sysmac Studio online with the Controller.
2
Click the
Edit Unit Operation Settings
Button for the Unit to which to transfer the Unit opera-
tion settings.
3
Click the
Transfer to Unit
Button on the Unit Operation Settings Tab Page.
One of the following messages is displayed depending on whether the Unit needs to be
restarted.
Transfer to NX Unit will be executed. Do you want to continue?
Transfer to NX Unit will be executed. The Unit will be restarted after the completion because
there is a change in the settings that require restarting. I/O communications with the communi-
cations master will be stopped by this operation. Are you sure you want to execute the transfer?
4
Click the
Yes
Button.
The Unit operation settings are transferred.
Precautions for Correct Use
• If a restart is necessary, the entire Slave Terminal is restarted. The EtherCAT master may
detect an error when the Slave Terminal is restarted after operations are performed with a
direct USB connection between the Sysmac Studio and EtherCAT Coupler Unit. If an error is
detected, you need to reset the error in the EtherCAT master.
Refer to
9-4 Transferring and Comparing Settings
on page 9-34 for a transfer method that
does not produce an error on the EtherCAT master.
• When the Slave Terminal is restarted, all of the Units on the Slave Terminal perform the same
operation as when the power supply is cycled. Refer to the manuals for the specific Units for
the operation that is performed when the power supply is turned ON.
A-2-2
Transferring the Unit Operation Settings
WARNING
Always confirm safety at the destination node before you transfer Unit configuration
information, parameters, settings, or other data from tools such as the Sysmac Studio.
The devices or machines may operate unexpectedly, regardless of the operating mode
of the Controller.
Summary of Contents for NX-ECC201
Page 38: ...Sections in this Manual 36 NX series EtherCAT Coupler Unit User s Manual W519...
Page 46: ...1 EtherCAT Networks 1 8 NX series EtherCAT Coupler Unit User s Manual W519...
Page 56: ...2 Features and System Configuration 2 10 NX series EtherCAT Coupler Unit User s Manual W519...
Page 82: ...4 Part Names and Functions 4 14 NX series EtherCAT Coupler Unit User s Manual W519...
Page 100: ...5 Designing the Power Supply System 5 18 NX series EtherCAT Coupler Unit User s Manual W519...
Page 214: ...9 Setting Up Slave Terminals 9 44 NX series EtherCAT Coupler Unit User s Manual W519...
Page 254: ...11 EtherCAT Coupler Unit Functions 11 30 NX series EtherCAT Coupler Unit User s Manual W519...
Page 278: ...12 Communications Performance 12 24 NX series EtherCAT Coupler Unit User s Manual W519...
Page 340: ...14 Maintenance and Inspection 14 8 NX series EtherCAT Coupler Unit User s Manual W519...
Page 400: ...Appendices A 60 NX series EtherCAT Coupler Unit User s Manual W519...
Page 401: ...Index 1 NX series EtherCAT Coupler Unit User s Manual W519 I Index...
Page 405: ......