9 - 9
9 Setting Up Slave Terminals
NX-series EtherCAT Coupler Unit User’s Manual (W519)
9-
2 Sett
ing
Slave T
er
m
inal
P
a
ra
m
ete
rs
9
9-2-
3 Setting the Un
it Co
nfigur
ation Informa
tion
NX Unit Mounting
Setting
This setting enables or disables the mounting of an NX
Unit. You cannot directly edit these settings in the
EtherCAT Coupler Unit.
---
---
Serial Number
This is the serial number of the EtherCAT Coupler Unit.
You can get the serial number to set the serial number
of the actual EtherCAT Coupler Unit.
---
---
Supply Power/Avail-
able Power [W]
The power that is currently drawn by the NX Units and
the maximum available power supply capacity are
given.
---
-/10.00
Unit width [mm]
This is the width of the EtherCAT Coupler Unit.
---
46
I/O allocation settings
Yes
These are the I/O allocation settings for the EtherCAT
Coupler Unit. Click the
Edit I/O Allocation Settings
Button to edit these settings.
---
Refer to
9-13.
Unit operation set-
tings
Yes
These are the Unit operation settings for the EtherCAT
Coupler Unit. Click the
Edit Unit Operation Settings
Button to edit these settings.
---
Refer to
9-23.
Number of mounted
Units
This is the number of mounted NX Units.
---
---
NX Unit Connection
Time (s)
Yes
This is the wait time for the NX Units to connect to the
Slave Terminal.
3 to 200 s
3 s
Serial Number Check
Method
Yes
Set this setting to
Setting = Actual device
to compare
the serial numbers of the NX Units at these times: when
the power is turned ON and after the EtherCAT Coupler
Unit is restarted. The serial numbers of the NX Units
saved in the Unit configuration information are com-
pared with the actual serial numbers of the NX Units.
*1
If differences are found, a Unit Configuration Verifica-
tion Error will occur.
No check.
Setting =
Actual
device
No check.
*1. If this setting is set to
Setting = Actual device
and you replace an NX Unit in the Slave Terminal, an Unit Con-
figuration Verification Error will occur. A Unit Configuration Verification Error will also occur if you swap the
mounting position of two Units of the same model. If it becomes necessary to replace an NX Unit, or swap the
mounting positions of two Units of the same model while this setting is set to
Setting = Actual device
, you must
correct the Unit configuration information and download it to the EtherCAT Coupler Unit. Set this parameter to
Setting = Actual device
if strict management of the equipment configuration is required.
Setting
Setta-
ble
Description
Data
range
Default
Summary of Contents for NX-ECC201
Page 38: ...Sections in this Manual 36 NX series EtherCAT Coupler Unit User s Manual W519...
Page 46: ...1 EtherCAT Networks 1 8 NX series EtherCAT Coupler Unit User s Manual W519...
Page 56: ...2 Features and System Configuration 2 10 NX series EtherCAT Coupler Unit User s Manual W519...
Page 82: ...4 Part Names and Functions 4 14 NX series EtherCAT Coupler Unit User s Manual W519...
Page 100: ...5 Designing the Power Supply System 5 18 NX series EtherCAT Coupler Unit User s Manual W519...
Page 214: ...9 Setting Up Slave Terminals 9 44 NX series EtherCAT Coupler Unit User s Manual W519...
Page 254: ...11 EtherCAT Coupler Unit Functions 11 30 NX series EtherCAT Coupler Unit User s Manual W519...
Page 278: ...12 Communications Performance 12 24 NX series EtherCAT Coupler Unit User s Manual W519...
Page 340: ...14 Maintenance and Inspection 14 8 NX series EtherCAT Coupler Unit User s Manual W519...
Page 400: ...Appendices A 60 NX series EtherCAT Coupler Unit User s Manual W519...
Page 401: ...Index 1 NX series EtherCAT Coupler Unit User s Manual W519 I Index...
Page 405: ......