![background image](http://html1.mh-extra.com/html/omron/nx-ecc201/nx-ecc201_user-manual_742778147.webp)
7 - 15
7 Wiring
NX-series EtherCAT Coupler Unit User’s Manual (W519)
7-2 C
onn
ectin
g t
h
e Po
wer Su
ppl
y and
Gro
und
Wir
e
s
7
7-2
-5 Wiring to the Screwl
ess C
lamping T
erminal Block
*1. Some AWG14 wires exceed 2.0 mm
2
and cannot be used in the screwless clamping terminal block.
When you use any ferrules other than those in the above table, crimp them to the twisted wires so that
the following processed dimensions are achieved.
Using Twisted Wires/Solid Wires
If you use the twisted wires or the solid wires, the applicable wire range and conductor length (strip-
ping length) are as follows.
Use the twisted wires to connect the ground wire to a ground of 100
Ω
or less. Do not use the solid
wires.
Terminal
types
Manufac-
turer
Ferrule
model
Applica-
ble wire
(mm
2
(AWG))
Crimping tool
Terminals
other than
ground ter-
minals
Phoenix
Contact
AI0,34-8
0.34 (#22)
Phoenix Contact (The figure in parentheses is the
applicable wire size.)
CRIMPFOX 6 (0.25 to 6 mm
2
, AWG24 to 10)
AI0,5-8
0.5 (#20)
AI0,5-10
AI0,75-8
0.75 (#18)
AI0,75-10
AI1,0-8
1.0 (#18)
AI1,0-10
AI1,5-8
1.5 (#16)
AI1,5-10
Ground ter-
minals
AI2,5-10
2.0
*1
Terminals
other than
ground ter-
minals
Weidmuller
H0.14/12
0.14 (#26)
Weidmuller (The figure in parentheses is the appli-
cable wire size.)
PZ6 Roto (0.14 to 6 mm
2
, AWG26 to 10)
H0.25/12
0.25 (#24)
H0.34/12
0.34 (#22)
H0.5/14
0.5 (#20)
H0.5/16
H0.75/14
0.75 (#18)
H0.75/16
H1.0/14
1.0 (#18)
H1.0/16
H1.5/14
1.5 (#16)
H1.5/16
Terminal types
Applicable wire range
Conductor length (stripping length)
Ground terminals
2.0 mm
2
9 to 10 mm
Terminals other than
ground terminals
0.08 to 1.5 mm
2
AWG28 to 16
8 to 10 mm
8 to 10mm
2.4 mm max.
(Terminals other than ground terminals)
2.7 mm max.
(Ground terminals)
1.6 mm max.
(Terminals other than ground terminals)
2.0 mm max.
(Ground terminals)
Summary of Contents for NX-ECC201
Page 38: ...Sections in this Manual 36 NX series EtherCAT Coupler Unit User s Manual W519...
Page 46: ...1 EtherCAT Networks 1 8 NX series EtherCAT Coupler Unit User s Manual W519...
Page 56: ...2 Features and System Configuration 2 10 NX series EtherCAT Coupler Unit User s Manual W519...
Page 82: ...4 Part Names and Functions 4 14 NX series EtherCAT Coupler Unit User s Manual W519...
Page 100: ...5 Designing the Power Supply System 5 18 NX series EtherCAT Coupler Unit User s Manual W519...
Page 214: ...9 Setting Up Slave Terminals 9 44 NX series EtherCAT Coupler Unit User s Manual W519...
Page 254: ...11 EtherCAT Coupler Unit Functions 11 30 NX series EtherCAT Coupler Unit User s Manual W519...
Page 278: ...12 Communications Performance 12 24 NX series EtherCAT Coupler Unit User s Manual W519...
Page 340: ...14 Maintenance and Inspection 14 8 NX series EtherCAT Coupler Unit User s Manual W519...
Page 400: ...Appendices A 60 NX series EtherCAT Coupler Unit User s Manual W519...
Page 401: ...Index 1 NX series EtherCAT Coupler Unit User s Manual W519 I Index...
Page 405: ......