• The following table shows the bit configuration of the Reset/External Input Status object.
• Only bits 5 and 7 are valid for the NX-EC0212 and NX-EC0222.
*1. The indicated count direction is based on the setting of the Encoder Count Direction parameter. Because
this is the count direction for the latest pulse input, the direction given by the Count Direction Flag and the
difference between the previous and current values of the Encoder Present Position parameter may not
agree if there is oscillation in the pulse input from the encoder.
Index
(hex)
Subin-
dex
(hex)
Object name
Default
Data range
Unit
Data type Access
I/O
allo-
cat-
ion
Data
attri-
bute
6001
---
Reset/External Input Sta-
tus
---
---
---
---
---
---
---
00
Number of Entries
*1
*1. The values for the NX-EC0112, NX-EC0122, NX-EC0132, or NX-EC0142 are 1. The values for the NX-EC0212 or
NX-EC0222 are 2.
*1
---
USINT
RO
No
---
01
Ch1 Reset/External Input
Status
*2
*2. The values for the NX-EC0112, NX-EC0122, NX-EC0132, or NX-EC0142 are 08 hex. The values for the NX-EC0212 or
NX-EC0222 are 00 hex.
00 to FF hex
---
BYTE
RO
Yes
---
02
Ch2 Reset/External Input
Status
*3
*3. This object does not exist on the NX-EC0112, NX-EC0122, NX-EC0132, and NX-EC0142.
00 hex
00 to FF hex
---
BYTE
RO
Yes
---
Bit
Status name
Description
0
External Input 0 Status
1: External input 0 ON.
0: External input 0 OFF.
1
External Input 1 Status
1: External input 1 ON.
0: External input 1 OFF.
2
External Input 2 Status
1: External input 2 ON.
0: External input 2 OFF.
3
External Input Enabled
*1
*1. The external input is enabled if the External Input Function Selection parameter is set correctly
and the external input is enabled. If the External Input Function Selection parameter is set more
than once for the same input, the external input is disabled.
1: External input enabled.
0: External input disabled.
4
External Reset Enabled
1: Reset for external reset enabled.
0: Reset for external reset disabled.
5
Phase Z Reset Enabled
1: Reset for phase-Z signal enabled.
0: Reset for phase-Z signal disabled.
6
External Reset Completed Flag
1: Reset for external reset occurred.
0: Reset for external reset did not occur.
7
Phase Z Reset Completed Flag
1: Reset for phase-Z signal occurred.
0: Reset for phase-Z signal did not occur.
Summary of Contents for NX-EC0112
Page 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Page 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Page 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Page 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Page 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Page 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Page 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Page 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Page 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Page 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Page 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...