7 SSI Input Units
7 - 36
NX-series Position Interface Units User’s Manual (W524)
7-8
Setting Methods
This section describes the setting methods for the SSI Input Units.
You can use an SSI Input Unit as an encoder axis input device if you also use the MC Function Module.
This section describes the settings for using an NJ/NX-series Controller and the MC Function Module to
control SSI Input Units.
For details on the functions of the MC Function Module, refer to the
NJ/NX-series CPU Unit Motion
Control User’s Manual
(Cat. No. W507).
Precautions for Correct Use
To assign a Position Interface Unit to an axis in the MC Function Module, you must assign
NX
Unit I/O Data Active Status
in the EtherCAT Coupler Unit. Replace “
” with 15, 31,
63, or 125 according to the highest NX Unit number of the EtherCAT Coupler Units. Refer to the
N
X-series EtherCAT Coupler Unit User’s Manual
(Cat. No. W519) for details.
SSI Input Units are mounted after an EtherCAT Coupler Unit to build an NX Unit Slave Terminal. The
Slave Terminal is connected through EtherCAT communications.
Refer to the
NX-series EtherCAT Coupler Unit User’s Manual
(Cat. No. W519) for information on how to
build NX Unit systems.
7-5 Terminal Block Arrangement
on page 7-10 for information on wiring SSI Input Units to
external devices, such as SSI encoders.
This section describes the minimum parameter settings that are required to use SSI Input Units with the
MC Function Module.
on page 7-38 for information on SSI Input Unit parameters.
You can set SSI Input Unit parameters for a variety of SSI encoder communications data formats, tim-
ings, coding methods, and other settings.
Set the parameters based on the communications specifications of the connected SSI encoder.
on page 7-40 for information on SSI communications settings.
Use the Encoder Count Direction parameter to specify the incrementing/decrementing direction in the
Unit in comparison to the incrementing/decrementing direction of the SSI Encoder.
You can reverse the count direction from the Unit for SSI encoders that provide the absolute position in
the communications data.
The default setting for the SSI Input Unit is 0 (Not to invert the sign).
on page 7-50 for information on setting the count direction.
7-8-1
Building and Wiring the System
7-8-2
Setting Examples
Setting Up SSI Communications
Count Direction Setting
Summary of Contents for NX-EC0112
Page 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Page 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Page 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Page 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Page 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Page 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Page 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Page 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Page 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Page 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Page 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...