![Omron NX-EC0112 User Manual Download Page 237](http://html1.mh-extra.com/html/omron/nx-ec0112/nx-ec0112_user-manual_742777237.webp)
7 - 31
7 SSI Input Units
NX-series Position Interface Units User’s Manual (W524)
7-7 I/O Da
ta S
p
ec
ification
s
7
7-7
-2 Dat
a Det
ails
The data items that you can allocate to I/O for a Two-input Unit are listed in the following table.
This section describes the data configuration for each of the 7 data items for I/O allocation.
The bit configuration of the SSI Status parameter is given in the following table.
n: Channel number
NX-ECS212
Area
Data item
Size
(bytes)
Data type
Default
*1
*1. The
Default
column shows the data item that are set when the Unit is shipped from the factory. You can allocate
other data items.
MC Function
Module PDO
*2
*2. These PDOs are required to use the MC Function Module.
Input
SSI Status 1
1
BYTE
Yes
SSI Communications Error Code 1
1
BYTE
Yes
Encoder Present Position 1
4
DINT
Yes
Yes
Status Data 1
4
DWORD
Yes
Encoder Present Position Refresh
Count 1
2
UINT
Time Stamp 1
*3
*3. An EtherCAT Coupler Unit with unit version 1.1 or later is required.
8
ULINT
SSI Status 2
1
BYTE
Yes
SSI Communications Error Code 2
1
BYTE
Yes
Encoder Present Position 2
4
DINT
Yes
Yes
Status Data 2
4
DWORD
Yes
Encoder Present Position Refresh
Count 2
2
UINT
Time Stamp 2
*3
8
ULINT
Output
SSI Operation Command 1
2
WORD
SSI Operation Command 2
2
WORD
7-7-2
Data Details
SSI Status
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
---
---
---
---
---
CRUNn
ERRn
REFn
Abbr.
Data
Description
REFn
Data Refresh Status
This indicates when the position data changes from its previous
value.
This bit toggles between 0 and 1 every time the data changes.
ERRn
SSI Communications Error Sta-
tus
1: Error occurred.
0: No errors occurred.
CRUNn
SSI Communications Enabled
*1
*1. The status of this bit depends on the value of the SSI Communications Enable bit in the SSI Operation Com-
mand parameter. Refer to
on page 7-35 for information on the SSI Operation Com-
mand parameter.
1: SSI communications enabled.
0: SSI communications disabled.
Summary of Contents for NX-EC0112
Page 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Page 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Page 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Page 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Page 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Page 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Page 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Page 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Page 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Page 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Page 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...