![background image](http://html1.mh-extra.com/html/omron/nx-ec0112/nx-ec0112_user-manual_742777426.webp)
Appendices
A - 38
NX-series Position Interface Units User’s Manual (W524)
• Set this object to the maximum value of the counter.
• The maximum value is the same for either a ring counter or linear counter.
• Set this object to the minimum value of the counter.
• The maximum value is the same for either a ring counter or linear counter.
• The following table shows the settings for the Pulse Input Method object.
Index
(hex)
Subin-
dex
(hex)
Object name
Default
Data range
Unit
Data type Access
I/O
allo-
cat-
ion
Data
attri-
bute
5001
---
Maximum Counter
Value
---
---
---
---
---
---
---
00
Number of Entries
*1
*1. The values for the NX-EC0112, NX-EC0122, NX-EC0132, or NX-EC0142 are 1. The values for the NX-EC0212 or
NX-EC0222 are 2.
*1
---
USINT
RO
No
---
01
Ch1 Maximum Coun-
ter Value
2147483647
1 to
2147483647
pulse
DINT
RW
No
Y
02
Ch2 Maximum Coun-
ter Value
*2
*2. This object does not exist on the NX-EC0112, NX-EC0122, NX-EC0132, and NX-EC0142.
2147483647
1 to
2147483647
pulse
DINT
RW
No
Y
Index
(hex)
Subin-
dex
(hex)
Object name
Default
Data range
Unit
Data type Access
I/O
allo-
cat-
ion
Data
attri-
bute
5002
---
Minimum Counter
Value
---
---
---
---
---
---
---
00
Number of Entries
*1
*1. The values for the NX-EC0112, NX-EC0122, NX-EC0132, or NX-EC0142 are 1. The values for the NX-EC0212 or
NX-EC0222 are 2.
*1
---
USINT
RO
No
---
01
Ch1 Minimum Coun-
ter Value
−
2147483648
−
214748364
8 to 0
pulse
DINT
RW
No
Y
02
Ch2 Minimum Coun-
ter Value
*2
*2. This object does not exist on the NX-EC0112, NX-EC0122, NX-EC0132, and NX-EC0142.
−
2147483648
−
214748364
8 to 0
pulse
DINT
RW
No
Y
Index
(hex)
Subin-
dex
(hex)
Object name
Default
Data range
Unit
Data type Access
I/O
allo-
cat-
ion
Data
attri-
bute
5003
---
Pulse Input Method
---
---
---
---
---
---
---
00
Number of Entries
*1
*1. The values for the NX-EC0112, NX-EC0122, NX-EC0132, or NX-EC0142 are 1. The values for the NX-EC0212 or
NX-EC0222 are 2.
*1
---
USINT
RO
No
---
01
Ch1 Pulse Input Method
2
1 to 4
---
USINT
RW
No
Y
02
Ch2 Pulse Input Method
*2
*2. This object does not exist on the NX-EC0112, NX-EC0122, NX-EC0132, and NX-EC0142.
2
1 to 4
---
USINT
RW
No
Y
Set value
Description
0
Not Supported
1
Phase differential pulse (x2)
2
Phase differential pulse (x4)
3
Pulse + Direction
4
Up and Down pulses
Summary of Contents for NX-EC0112
Page 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Page 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Page 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Page 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Page 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Page 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Page 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Page 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Page 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Page 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Page 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...