10 Troubleshooting
10 - 20
NX-series Position Interface Units User’s Manual (W524)
Event name
NX Unit Clock Not Synchronized Error
Event code
80240000 hex
Meaning
An error occurred in the clock information between the EtherCAT Coupler Unit and the NX Unit.
Source
Depends on where the Sysmac
Studio is connected and the sys-
tem configuration.
Source details
NX Unit
Detection
timing
Continuously
Error
attributes
Level
Minor fault
Recovery
Restart the NX
Unit.
Log category
System
Effects
User program
Continues.
Operation
The NX Unit will continue to operate.
Input data: Updating input values stops.
Output data: The external outputs are turned OFF.
The pulse output value depends on the Load Rejec-
tion Output Setting.
Sys-
tem-defined
variables
Variable
Data type
Name
None
---
---
Cause and
correction
Assumed cause
Correction
Prevention
There is a hardware error in the
NX Unit.
If the error occurred in only a spe-
cific NX Unit in the Slave Terminal,
replace the NX Unit.
If the error occurred in all of the
NX Units on the Slave Terminal
except for the System Units,
replace the EtherCAT Coupler
Unit.
None
There is a hardware error in the
EtherCAT Coupler Unit.
Attached
information
None
Precautions/
Remarks
None
Summary of Contents for NX-EC0112
Page 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Page 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Page 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Page 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Page 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Page 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Page 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Page 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Page 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Page 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Page 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...