![Omron NX-EC0112 User Manual Download Page 354](http://html1.mh-extra.com/html/omron/nx-ec0112/nx-ec0112_user-manual_742777354.webp)
9 Application Example
9 - 14
NX-series Position Interface Units User’s Manual (W524)
9-4-2
Ladder Programming
MV_REL
MC_MoveRelative
Axis
Axis
Done
Busy
Active
CommandAborted
Error
ErrorID
Execute
Distance
Velocity
Acceleration
Deceleration
Jerk
BufferMode
IMD_STP
MC_ImmediateStop
Axis
Axis
Done
Busy
CommandAborted
Error
ErrorID
Execute
StopMode
StartPg
MoveStart
RunOutput
End0
Imd_Stp_D
Lock0
Start0
_EC_PDSlavTbl[MC_Axis000.Cfg.NodeAddress]
_EC_CommErrTbl[MC_Axis000.Cfg.NodeAddress]
Lock0
MC_Axis000
RunOutput
PWR
MC_Power
Axis
Axis
Status
Busy
Error
ErrorID
Enable
MC_Axis000
Start0
Mv_Rel_D
Start0
InPosition
End0
MC_Axis000
Move_Distance
Move_Velocity
Move_Acc
Move_Dec
MC_Axis000
MC_Axis000
MC_Axis000
Mv_Rel_D
DrvEmInput
Stop0
Imd_Stp_D
Reset_D
ResetDrvErr
Stop0
ResetOn
MC_Axis000
MC_Axis000
RESET
MC_Reset
Axis
Axis
Done
Busy
Failure
Error
ErrorID
Execute
If the
StartPg
input is TRUE, the status of process data communications is checked to see if communications are active and normal.
If process data communications are active and normal, the Servo for axis 0 is turned ON and the
RunOutput
output is turned ON.
If the
MoveStart
input changes to TRUE, the positioning execution condition,
Start0
, changes to TRUE.
When the relative positioning instruction is completed and the
InPosition
input changes to TRUE, the positioning completion condition,
End0
,
If the positioning execution condition,
Start0
, is TRUE, relative positioning is executed.
If the
DrvEmInput
input is TRUE, the Immediate Stop (MC_ImmediateStop) instruction is executed and positioning is stopped immediately.
If the
ResetOn
input is TRUE, the
ResetDrvErr
output changes to TRUE and the error in the MC Function Module is reset.
Summary of Contents for NX-EC0112
Page 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Page 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Page 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Page 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Page 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Page 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Page 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Page 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Page 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Page 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Page 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...