6 - 43
6 Incremental Encoder Input Units
NX-series Position Interface Units User’s Manual (W524)
6
-8 Sett
ing
Meth
od
s
6
6-
8-1 Building and
Wiring the
S
ystem
6-8
Setting Methods
This section describes the setting methods for the Incremental Encoder Input Units.
You can use an Incremental Encoder Input Unit as an encoder axis input device if you also use the MC
Function Module.
This section describes the settings for using an NJ/NX-series Controller and the MC Function Module to
control Incremental Encoder Input Units.
For details on the functions of the MC Function Module, refer to the
NJ/NX-series CPU Unit Motion
Control User’s Manual
(Cat. No. W507).
Precautions for Correct Use
To assign a Position Interface Unit to an axis in the MC Function Module, you must assign
NX
Unit I/O Data Active Status
in the EtherCAT Coupler Unit. Replace “
” with 15, 31,
63, or 125 according to the highest NX Unit number of the EtherCAT Coupler Units. Refer to the
N
X-series EtherCAT Coupler Unit User’s Manual
(Cat. No. W519) for details.
Incremental Encoder Input Units are mounted after an EtherCAT Coupler Unit to build an NX Unit Slave
Terminal. The Slave Terminal is connected through EtherCAT communications.
Refer to the
NX-series EtherCAT Coupler Unit User’s Manual
(Cat. No. W519) for information on how to
build NX Unit systems.
Refer to
6-5 Terminal Block Arrangement
on page 6-11 for information on wiring external devices to an
Incremental Encoder Input Unit, such as encoders or external sensors for latching.
The functional specifications of the Incremental Encoder Input Unit are given below.
This section describes the minimum parameter settings that are required to use Incremental Encoder
Input Units with the MC Function Module.
on page 6-46 for information on the parameters of the Incremental Encoder
Input Units.
6-8-1
Building and Wiring the System
6-8-2
Counter Specifications
Function
Specifications
Counter range
80000000 to 7FFFFFFF hex
Pulse input method
Phase differential pulse (multiplication x2/4), pulse + direction, or up
and down pulses
Counting speed
Voltage input: 500 kHz
Line receiver input: 4 MHz
Gate control (counter enabled/disabled) Encoder counter operation command or external input
Resetting
Encoder counter operation command, external input, or phase-Z input
Preset
Encoder counter operation command
Latching
Encoder counter operation command, external input, or phase-Z input
6-8-3
Setting Examples
Summary of Contents for NX-EC0112
Page 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Page 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Page 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Page 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Page 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Page 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Page 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Page 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Page 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Page 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Page 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...