9 - 11
9 Application Example
NX-series Position Interface Units User’s Manual (W524)
9-3
S
e
ttin
g
Exam
ples
9
9-3-
3 I/O Assignment
s and Settings
Assign the process data for the Digital Input Units to the axis functions as shown below in the detailed
settings on the Axis Basic Settings Display.
You can review the Pulse Output Unit process data that was automatically assigned in the detailed set-
tings on the Axis Basic Settings Display.
Additional Information
You can use external inputs 0 and 1 on the Pulse Output Unit as external latch inputs 1 and 2
by setting the External Input Function Selection parameters. If you perform homing with the MC
Function Module, external latch 1 (external input 0) is used as the home input. If you do not use
external latch 2 (external input 1) for latching, select a general input for the External Input Func-
tion Selection parameter. If you select a general input, you can use the external input as a limit
input or other input.
Application Example
If you use the MC Function Module and use and the latching function of the Pulse Output
Unit only for homing, set the external input 0 of the Pulse Output Unit as the external latch
input 1 and use it as the home input. You can set external input 1 as a general input and
use it as the home proximity input or another input. In this case, you can change the set-
tings of the digital inputs of the MC Function Module to assign the input bits.
Refer to
External Input Function Selection
on page 8-65 for the External Input Function Selec-
tion parameters of the Pulse Output Unit. For the digital input settings of the MC Function Mod-
ule,
Function
Device
Process data
Remarks
Positive drive prohibit
input
NX Unit No. 3: NX-ID3417
(Digital Input Unit)
6000 hex-01 hex
(digital inputs)
Specifies the positive limit input
(IN0).
Negative drive pro-
hibit input
NX Unit No. 3: NX-ID3417
(Digital Input Unit)
6000 hex-02 hex
(digital inputs)
Specifies the negative limit input
(IN1).
Immediate stop input
NX Unit No. 3: NX-ID3417
(Digital Input Unit)
6000 hex-03 hex
(digital inputs)
Specifies the immediate stop
input (IN2).
Home proximity input
NX Unit No. 3: NX-ID3417
(Digital Input Unit)
6000 hex-04 hex
(digital inputs)
Specifies the home proximity
input (IN3).
Summary of Contents for NX-EC0112
Page 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Page 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Page 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Page 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Page 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Page 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Page 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Page 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Page 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Page 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Page 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...