6 - 59
6 Incremental Encoder Input Units
NX-series Position Interface Units User’s Manual (W524)
6-
9 Fu
nct
ion
s
6
6-
9-7 Co
unter Pr
eset
You can preset a value in the Preset Command Value parameter for each channel and change the Pre-
set Execution bit in the Encoder Counter Operation Command parameter from 0 to 1 to preset the
counter value.
When this is performed, the counter value is overwritten with the value in the Preset Command Value
parameter.
Encoder Counter Operation Command
on page 6-40 for information on the Preset Execution
bit.
If the Preset Command Value parameter is allocated in the output area, enter the command value
directly in that area.
If the Preset Command Value parameter is not allocated in the output area, use message communica-
tions to write the value to the Unit. If the Preset Command Value parameter is not allocated in the out-
put area, the default for it is 0.
on page 6-42 for details on the Preset Command Value parameter.
If you set a value for the Preset Command Value that is outside of the valid counter value range and
attempt to preset the counter to that value, the value of the counter will not change and the Preset
Command Value Invalid Flag in the Encoder Counter Status parameter will change to 1. To reset the
Preset Command Value Invalid Flag to 0, set a value that is within the valid counter value range in the
Preset Command Value parameter and preset the counter again or reset the counter.
You can latch the counter value for each counter.
There are the following two latch methods:
• Latching with the Internal Latch Execution bit
• Latching with an external input
Change the Internal Latch Execution bit in the Encoder Counter Operation Command parameter from 0
to 1 to latch the counter. You can allocate the latch data in an I/O data input area.
Refer to
Encoder Counter Operation Command
on page 6-40 for information on the Internal Latch Exe-
cution bit.
You can select the external input latch trigger from the external inputs (I0, I1, and I2) and the encoder’s
phase-Z signal.
Latching with an external input (I0, I1, or I2) is supported only by the NX-EC0112, NX-EC0122,
NX-EC0132, and NX-EC0142.
on page 6-41 for information on latching for an external input.
6-9-9 External Input Function Selection
on page 6-62 for information on the external inputs (I0,
I1, and I2).
6-9-7
Counter Preset
6-9-8
Latching
Latching with the Internal Latch Execution Bit
Latching with an External Input
Summary of Contents for NX-EC0112
Page 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Page 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Page 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Page 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Page 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Page 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Page 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Page 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Page 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Page 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Page 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...