8-11 Specifications
This section provides the general specifications, external I/O specifications, and performance specifica-
tions for the Pulse Output Unit.
The general specifications of the Pulse Output Unit are given below.
8-11-1 General Specifications
Item
Specification
Number of pulse output channels 1
Pulse output interface
Open collector output
Maximum pulse output speed
500 kpps
Pulse output method
Forward/reverse direction pulse outputs or Pulse + direction out-
puts
Control unit
Pulses
Position control range
−
2,147,483,648 to 2,147,483,647 pulses
Velocity control range
1 to 500,000pps
Control I/O
Output signals
3
The outputs are forward direction pulse output, reverse direction
pulse output, and external output.
*1
*1. You can use the external output as an error counter reset output.
Input signals
2
The inputs are external inputs.
*2
*2. You can use the inputs as latch inputs.
NX Unit power consumption
NX-PG0112: 0.80 W max.
NX-PG0122: 0.90 W max.
I/O power supply voltage
20.4 to 28.8 VDC (24 VDC +20%/
−
15%)
Current consumption from I/O
power supply
NX-PG0112/-PG0122: 20 mA max.
I/O power supply method
NX bus
Weight
NX-PG0112/-PG0122: 70 g max.
Dimensions (Width × Height ×
Depth)
NX-PG0112/-PG0122: 12 × 100 × 71 mm
I/O data size
*3
*3. This is the default set value.
NX-PG0112/-PG0122: Inputs: 18 bytes, Outputs: 14 bytes
Number of I/O entry mappings
*3
NX-PG0112/-PG0122: Inputs: 1, Outputs: 1
Cable length
NX-PG0112/-PG0122: 3 m max.
Summary of Contents for NX-EC0112
Page 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Page 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Page 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Page 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Page 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Page 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Page 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Page 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Page 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Page 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Page 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...