1 Features and System Configuration
1 - 18
NX-series Position Interface Units User’s Manual (W524)
The following table lists the functions of the Pulse Output Unit.
on page 8-52 for details on these functions.
1-4-3
Functions of the Pulse Output Unit
Function
Description
Pulse output method
Allows you to select either forward/reverse direction pulse outputs or pulse +
direction outputs for the pulse output method.
Output mode selection
Allows you to select either position-synchronous pulse output or velocity-continu-
ous pulse output for the pulse output mode selection.
External output
You can use one external output as a error counter reset output when the Unit is
connected to a Servo Drive and used with the MC Function Module. You can also
control whether the external output is ON or OFF as a general output if you want
to manipulate a device variable directly without the MC Function Module.
Latching
You can latch the counter value of the pulse output. You can assign an external
input as a latch input to use two latches at the same time.
External input function selec-
tion
Two external inputs are provided. You can assign them either of the following
input functions: general input or latch input. You can also set the logic for each
input.
Load rejection output setting
Allows you to select the pulse stopping method when an error occurs.
You can select from the following two stopping methods: immediate stop or
deceleration stop with set deceleration rate.
Interpolation control for miss-
ing synchronization com-
mand
When a command is missing, the target position is predicted based on previous
commands to continue updating the target position.
Pulse direction change delay
When the Pulse Output Unit uses a velocity-continuous pulse output, this setting
sets the wait time when the pulse output direction changes.
I/O refreshing method setting Sets synchronous I/O refreshing
*1
or task period prioritized refreshing
*1, *2
for the
I/O refreshing
*3
method.
*1. You can select this option only when the Unit is used with a EtherCAT Coupler Unit with EtherCAT communi-
cations in DC Mode.
*2. Unit version 1.2 or later and an NX-ECC203 EtherCAT Coupler Unit are required.
*3. This is the data exchange with the Controller.
Summary of Contents for NX-EC0112
Page 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Page 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Page 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Page 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Page 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Page 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Page 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Page 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Page 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Page 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Page 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...