54
Basic Set-up
There are basic parameter that should be set first before setting other
parameter.
The parameter included in the basic set-up are listed in the table
below.
Please turn off the power after basic set-up and then restart it.
Please set up the control mode at SEt-41.
Basic Parameter
Basic Parameter
Event
SEt-41
Control Mode
SEt-51
Encoder Type
SEt-52
Motor Type
SEt-53
Motor Capacity
SEt-41 Set-up Value
Setting
Control Mode
/C-SEL OFF
/C-SEL ON
0
Position Mode
1
Speed Mode
10
Direction Change Speed Mode
12
Torque Limit Speed Mode
5
Zero Clamp Mode
2
Torque Mode
3
Multi-level Speed Mode
9
Speed Limit Torque Mode
Speed Limit Torque
Mode
Torque Mode
6
Speed Mode
Torque Mode
Speed Mode
7
Po Torque Mode
Position Mode
Torque Mode
8
Po Speed Mode
Position Mode
Speed Mode
13
Po Multi-level Speed
Mode
Position Mode
Multi-level Speed
Mode
14
Speed + Multi-level Speed Mode
Speed Mode
Multi-level Speed
Mode
15
Multi-level Speed Mode
Torque Mode
Multi-level Speed
Mode
Summary of Contents for CSDP Plus
Page 1: ...Maximum Value for OEMs SM CSDP Plus Servo Drive User Manual...
Page 16: ...18...
Page 30: ...32 Higher Control Connector CN1 Circuit Diagram...
Page 33: ...35 Compact Absolute Encoder Wiring Serial Encoder Wiring...
Page 38: ...40...
Page 120: ...122...
Page 179: ...181 Speed Torque Curve...
Page 180: ...182...
Page 183: ...185 Speed Torque Curve...
Page 184: ...186...
Page 187: ...189...
Page 190: ...192 Speed Torque Curve...
Page 193: ...195...
Page 196: ...198...
Page 201: ...203...
Page 204: ...206...
Page 207: ...209...
Page 210: ...212...
Page 215: ...217...
Page 230: ...232...
Page 252: ...254...