SEt-44(2) Dynamic Brake After the Motor
Stopped
•
Setting range: 0 x 0 to 0 x 1
•
User Default: 0 x 1
•
Changes while the servo is OFF
The set values are as follows.
0: Disable the dynamic brake after the motor stopped
1: Keep the dynamic brake ON after the motor stopped
SEt-44(3) Emergency Stop Method
•
Setting range: 0 x 0 to 0 x 1
•
User Default: 0 x 0
•
Changes while the servo is OFF
The set values are as follows.
0: Stop by emergency stop torque (SEt-14, SEt-15)
1: Stop by 0 torque (PWM OFF)