137
SEt-07 Position Feedforward Filter
•
Setting range: 0 to 5000 rad/s
•
User Default: 0
•
Changes anytime
The filter is used to feedforward the differentiated position command.
This parameter is the cut-off frequency of the filter. If position
feedforward gain (SEt-34) is 0, this parameter is not valid. In the case
of an overshoot, please set the parameter to 0.
Please refer to the diagram below for the information about the usage
and the setting position of SEt-07.
SEt-08 DA Monitor Channel 1 Scale
•
Setting range: 1 to 65535/V
•
User Default: 500
•
Changes anytime
The servo drive can display the analog monitor signals with which the
user can check the actual control status through an oscilloscope.
Set the scale unit of analog monitor channel 1 at
SEt-08.