NUC126
Aug. 08, 2018
Page
814
of 943
Rev 1.03
NUC12
6 S
E
RI
E
S
T
E
CH
NI
CA
L R
E
F
E
RE
NCE
MA
NUA
L
1 = The slave select signal has changed to active.
Note:
The internal slave select signal is active high.
[8]
SSINAIF
Slave Select Inactive Interrupt Flag (for Slave Only)
This bit indicates that the internal slave select signal has changed to inactive. It is cleared
by software writes 1 to this bit
0 = The slave select signal has not changed to inactive.
1 = The slave select signal has changed to inactive.
Note:
The internal slave select signal is active high.
[7]
Reserved
Reserved.
[6]
SLVBEIF
Slave Bit Count Error Interrupt Flag (for Slave Only)
0 = Slave bit count error event does not occur.
1 = Slave bit count error event occurs.
Note:
It is cleared by software write 1 to this bit.
[5]
SLVTOIF
Slave Time-out Interrupt Flag (for Slave Only)
0 = Slave time-out event did not occur.
1 = Slave time-out event occurred.
Note:
This bit is cleared by software writing 1 to it.
[4]
RXENDIF
Receive End Interrupt Flag
0 = Receive end event does not occur.
1 = Receive end event occurred.
Note:
This bit is cleared by software writing 1 to it.
[3]
RXSTIF
Receive Start Interrupt Flag
0 = Receive start event did not occur.
1 = Receive start event occurred.
Note:
This bit is cleared by software writing 1 to it.
[2]
TXENDIF
Transmit End Interrupt Flag
0 = Transmit end event did not occur.
1 = Transmit end event occurred.
Note:
This bit is cleared by software writing 1 to it.
[1]
TXSTIF
Transmit Start Interrupt Flag
0 = Transmit start event did not occur.
1 = Transmit start event occurred.
Note:
This bit is cleared by software writing 1 to it.
[0]
Reserved
Reserved.