RTC Time Alarm Register (RTC_TALM)
Register
Offset
R/W
Description
Reset Value
RTC_TALM
0x1C
R/W
RTC Time Alarm Register
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
TENHR
HR
15
14
13
12
11
10
9
8
Reserved
TENMIN
MIN
7
6
5
4
3
2
1
0
Reserved
TENSEC
SEC
Bits
Description
[31:24]
Reserved
Reserved.
[21:20]
TENHR
10-Hour
Time
Digit
of
Alarm
Setting
(0~2)
When RTC runs as 12-hour time scale mode, RTC_TIME[21] (the high bit of TENHR[1:0])
means AM/PM indication (If RTC_TIME[21] is 1, it indicates PM time message.)
[19:16]
HR
1-Hour Time Digit of Alarm Setting (0~9)
[15]
Reserved
Reserved.
[14:12]
TENMIN
10-Min Time Digit of Alarm Setting (0~5)
[11:8]
MIN
1-Min Time Digit of Alarm Setting (0~9)
[7]
Reserved
Reserved.
[6:4]
TENSEC
10-Sec Time Digit of Alarm Setting (0~5)
[3:0]
SEC
1-Sec Time Digit of Alarm Setting (0~9)
Note:
1.
RTC_TALM is a BCD digit counter and RTC will not check loaded data.
2.