NUC126
Aug. 08, 2018
Page
563
of 943
Rev 1.03
NUC12
6 S
E
RI
E
S
T
E
CH
NI
CA
L R
E
F
E
RE
NCE
MA
NUA
L
0 = Auto-convention Disabled.
1 = Auto-convention Enabled.
Note1:
If user enables auto convention function, the setting step must be done before
Answer to Reset (ATR) state and the first data must be 0x3B or 0x3F. After hardware
received first data and stored it at buffer, hardware will decided the convention and change
the CONSEL (SC_CTL[5:4]) bits automatically when received first data is 0x3B or 0x3F. If
received first byte is 0x3B, TS is direct convention, CONSEL (SC_CTL[5:4]) will be set to
00 automatically, otherwise the TS is inverse convention, and CONSEL (SC_CTL[5:4]) will
be set to 11.
Note2:
If the first data is not 0x3B or 0x3F, hardware will set ACERRIF (SC_INTSTS[10])
and generate an interrupt signal to inform CPU when ACERRIEN (SC_INTEN[10]) is
enabled.
[2]
TXOFF
TX Transition Disable Bit
This bit is used to disable Tx transmit function.
0 = The transceiver Enabled.
1 = The transceiver Disabled.
[1]
RXOFF
RX Transition Disable Bit
This bit is used to disable Rx receive function.
0 = The receiver Enabled.
1 = The receiver Disabled.
Note:
If AUTOCEN (SC_CTL[3]) is enabled, this field is ignored.
[0]
SCEN
SC Controller Enable Bit
Set this bit to 1 to enable SC operation function.
0 = SC will force all transition to IDLE state.
1 = SC controller is enabled and all function can work correctly.
Note:
SCEN must be set to 1 before filling in other SC registers, or smart card will not
work properly.