6.14.7
Register Description
RTC Initiation Register (RTC_INIT)
Register
Offset
R/W
Description
Reset Value
RTC_INIT
0x00
R/W
RTC Initiation Register
0x0000_0000
31
30
29
28
27
26
25
24
INIT
23
22
21
20
19
18
17
16
INIT
15
14
13
12
11
10
9
8
INIT
7
6
5
4
3
2
1
0
INIT
INIT[0]/ACTIVE
Bits
Description
[31:1]
INIT
RTC Initiation
When RTC block is first powered on, RTC is at reset state. User has to write a special
number 0xA5EB1357 to INIT to make RTC leaving reset state. Once the INIT is written as
0xA5EB1357 the RTC will be at normal active state permanently.
The INIT[31:1] is a write-only field and read value will be always 0.
[0]
INIT[0]/ACTIVE
RTC Active Status (Read Only)
0 = RTC is at reset state.
1 = RTC is at normal active state.