65E Turbo Motor Grader
Service Manual
10
-
15
Service 2.00_2013.03
Section 10
Diagnostic Fault Codes
611
4
Analog Input signal circuit for Load Govern kW Setpoint
-
Voltage Below Normal, or
Shorted to Low Source
611
3
Analog Input signal circuit for Load Govern kVAR Setpoint
-
Voltage Above Normal,
or Shorted to High Source
611
4
Analog Input signal circuit for Load Govern kVAR Setpoint
-
Voltage Below Normal,
or Shorted to Low Source
611
31
Analog Input signal for Load Govern kW Setpoint is set outside of acceptable
working limits
-
Condition Exists
611
4
'Off / Manual / Auto' switch circuit
-
Voltage Below Normal, or Shorted to Low Source
611
3
'Off / Manual / Auto' switch circuit
-
Voltage Above Normal, or Shorted to High
Source
611
31
Critical Scalar out
-
of
-
range
-
Condition Exists
611
31
Non
-
Critical Scalar out
-
of
-
range
-
Condition Exists
611
31
Fuel System Board (Slot 0) is missing, and or has not been installed correctly
-
Condition Exists
611
31
Base Board (Slot 1) is missing, and or has not been installed correctly
-
Condition
Exists
611
31
Generator Interface Board (Slot 2) is missing, and or has not been installed correctly
-
Condition Exists
611
31
Paralleling Board (Slot 3 is missing, and or has not been installed correctly
-
Condition Exists
611
31
LonWorks Board (Slot 4) is missing, and or has not been installed correctly
-
Condition Exists
611
31
Slot 5 Board is missing, and or has not been installed correctly
-
Condition Exists
611
31
Slot 6 Board is missing, and or has not been installed correctly
-
Condition Exists
611
31
Slot 7 Board is missing, and or has not been installed correctly
-
Condition Exists
611
31
LonWorks Board (Slot 4) is missing
-
Condition Exists
611
12
Controller Configuration Error
-
Bad Intelligent Device or Component
611
31
Run Relay Driver Contact Diagnostic has detected an error
-
Condition Exists
611
31
Common Warning Relay Driver Diagnostic has detected an error
-
Condition Exists
611
31
Operator Interface Mode Transition to Emergency Stop (due to E
-
Stop)
-
Condition
Exists
611
31
Operator Interface Mode Transition to Emergency Stop (due to Remote E
-
Stop)
-
Condition Exists
611
31
Emergency Stop Path Fuse Blown
-
Condition Exists
611
31
Generator announces to the Lonworks network that the Generator control switch is
not in Auto
-
Condition Exists
611
31
Due to an Overload or Underfrequency the Generator announces to the Lonworks
network that a Load Dump has occurred
-
Condition Exists
611
31
Generator announces to the Lonworks network that it is ready to accept a load
-
Condition Exists
611
31
Modem Failure
-
Condition Exists
SPN
FMI
Cummins Description
Summary of Contents for 65E Turbo Motor Grader
Page 2: ...This page intentionally left blank ...
Page 7: ...Service Manual Section 1 Electronic Display Service 2 00_2013 03 ...
Page 33: ...Service Manual Section 2 Engine Service 2 00_2013 03 ...
Page 34: ......
Page 75: ...Service Manual Section 3 Operator s Platform and Controls Service 2 00_2013 03 ...
Page 76: ......
Page 121: ...Service Manual Section 4 Transmission Service 2 00_2013 03 ...
Page 122: ......
Page 149: ...ERGOPOWER Geschäftsbereich Arbeitsmaschinen Antriebe und Achssysteme 2 1 Edition ...
Page 171: ......
Page 202: ...Order No 5871 146 002 ZF ERGOPOWER 6 WG 115 ZF Passau GmbH Donaustr 25 71 D 94 034 Passau ...
Page 330: ...Service Manual Section 5 Front Axle Service 2 00_2013 03 ...
Page 331: ......
Page 382: ...Service Manual Section 6 Rear Axle and Tandem Service 2 00_2013 03 ...
Page 383: ......
Page 456: ...Service Manual Section 7 Electrical Service 2 00_2013 03 ...
Page 457: ......
Page 471: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 4 Section 7 Electrical ...
Page 472: ...65E Turbo Motor Grader Service Manual 7 5 Service 2 00_2013 03 Section 7 Electrical ...
Page 473: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 6 Section 7 Electrical ...
Page 474: ...65E Turbo Motor Grader Service Manual 7 7 Service 2 00_2013 03 Section 7 Electrical ...
Page 475: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 8 Section 7 Electrical ...
Page 477: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 10 Section 7 Electrical ...
Page 478: ...65E Turbo Motor Grader Service Manual 7 11 Service 2 00_2013 03 Section 7 Electrical ...
Page 479: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 12 Section 7 Electrical ...
Page 480: ...65E Turbo Motor Grader Service Manual 7 13 Service 2 00_2013 03 Section 7 Electrical ...
Page 481: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 14 Section 7 Electrical ...
Page 519: ...Service Manual Section 8 Hydraulics Service 2 00_2013 03 ...
Page 520: ......
Page 641: ...Service Manual Section 9 Moldboard and Implement Service 2 00_2013 03 ...
Page 642: ......
Page 677: ...Service Manual Section 10 Diagnostic Fault Codes Service 2 00_2013 03 ...
Page 678: ......