Section 10
Diagnostic Fault Codes
611
31
Unable to complete remote connection via the Modem
-
Condition Exists
611
31
Lonworks Network Failure
-
Condition Exists
611
31
Permission to connect to a closed bus has not been received in the required time
-
Condition Exists
611
31
ECM base board is not responding to the Lonworks board
-
Condition Exists
611
31
Crank Relay Driver Contact Diagnostic has detected an error
-
Condition Exists
611
31
Crank Relay Driver Diagnostic has detected an error
-
Condition Exists
611
31
Fail to Start Relay Driver Diagnostic has detected an error
-
Condition Exists
611
31
Generator Set Fault Code has not been acknowledged
-
Condition Exists
611
6
Electronic Fuel Control Driver Diagnostic has detected a Grounded circuit condition
-
Current Above Normal, or Grounded Circuit
611
5
Electronic Fuel Control Driver Diagnostic has detected an Open circuit condition
-
Current Below Normal, or Open Circuit
611
31
'Not in Auto' LED Driver Diagnostic has detected an error
-
Condition Exists
611
31
'Warning' LED Driver Diagnostic has detected an error
-
Condition Exists
611
31
'Ready to Load' Output Relay Driver Diagnostic has detected an error
-
Condition
Exists
611
31
'Load Dump' Output Relay Driver Diagnostic has detected an error
-
Condition
Exists
611
31
Operator Interface Panel Power Relay Driver Diagnostic has detected an error
-
Condition Exists
611
31
Modem Power Relay Driver Diagnostic has detected an error
-
Condition Exists
611
31
'Run B+' Output Relay Driver Diagnostic has detected an error
-
Condition Exists
611
31
'Manual Run/Stop' LED Driver Diagnostic has detected an error
-
Condition Exists
611
31
'Exercise' LED Driver Diagnostic has detected an error
-
Condition Exists
611
31
'Remote Start' LED Driver Diagnostic has detected an error
-
Condition Exists
611
31
Sudden Vehicle Speed Deceleration
-
Condition Exists
611
16
Fuel Inlet Meter Device
-
Data Valid but Above Normal Operational Range
-
Moderately Severe Level
611
18
Fuel Inlet Meter Device flow demand lower than expected
-
Data Valid but Below
Normal Operational Range
-
Moderately Severe Level
611
31
Priming Pump Driver Diagnostic has detected an error
-
Condition Exists
611
31
Automatic Main Utility Module Status
-
Condition Exists
611
31
Generator Set Connected to Load
-
Condition Exists
611
31
Power Transferred From Utility to Genset
-
Condition Exists
611
31
Loss of AC Phase Voltage Sensing
-
Condition Exists
611
31
Controller Checksums Differ From Calibration Download
-
Condition Exists
611
31
AMF Board is Present But Not Enabled
-
Condition Exists
611
31
AMF Board is Not Present But Enabled
-
Condition Exists
SPN
FMI
Cummins Description
Summary of Contents for 65E Turbo Motor Grader
Page 2: ...This page intentionally left blank ...
Page 7: ...Service Manual Section 1 Electronic Display Service 2 00_2013 03 ...
Page 33: ...Service Manual Section 2 Engine Service 2 00_2013 03 ...
Page 34: ......
Page 75: ...Service Manual Section 3 Operator s Platform and Controls Service 2 00_2013 03 ...
Page 76: ......
Page 121: ...Service Manual Section 4 Transmission Service 2 00_2013 03 ...
Page 122: ......
Page 149: ...ERGOPOWER Geschäftsbereich Arbeitsmaschinen Antriebe und Achssysteme 2 1 Edition ...
Page 171: ......
Page 202: ...Order No 5871 146 002 ZF ERGOPOWER 6 WG 115 ZF Passau GmbH Donaustr 25 71 D 94 034 Passau ...
Page 330: ...Service Manual Section 5 Front Axle Service 2 00_2013 03 ...
Page 331: ......
Page 382: ...Service Manual Section 6 Rear Axle and Tandem Service 2 00_2013 03 ...
Page 383: ......
Page 456: ...Service Manual Section 7 Electrical Service 2 00_2013 03 ...
Page 457: ......
Page 471: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 4 Section 7 Electrical ...
Page 472: ...65E Turbo Motor Grader Service Manual 7 5 Service 2 00_2013 03 Section 7 Electrical ...
Page 473: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 6 Section 7 Electrical ...
Page 474: ...65E Turbo Motor Grader Service Manual 7 7 Service 2 00_2013 03 Section 7 Electrical ...
Page 475: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 8 Section 7 Electrical ...
Page 477: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 10 Section 7 Electrical ...
Page 478: ...65E Turbo Motor Grader Service Manual 7 11 Service 2 00_2013 03 Section 7 Electrical ...
Page 479: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 12 Section 7 Electrical ...
Page 480: ...65E Turbo Motor Grader Service Manual 7 13 Service 2 00_2013 03 Section 7 Electrical ...
Page 481: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 14 Section 7 Electrical ...
Page 519: ...Service Manual Section 8 Hydraulics Service 2 00_2013 03 ...
Page 520: ......
Page 641: ...Service Manual Section 9 Moldboard and Implement Service 2 00_2013 03 ...
Page 642: ......
Page 677: ...Service Manual Section 10 Diagnostic Fault Codes Service 2 00_2013 03 ...
Page 678: ......