SETUP PROCEDURE
3-25
3.3.10
Adjustment of GAP Sensor/I-Mark Sensor
Adjust the sensitivity of sensors.
As operational procedures for Gap1 sensor, GAP2 sensor, I-Mark1 sensor and I-Mark2 sensor
are all the same, here “Adjustment of GAP1 Sensor” is picked as an example for explanation.
1
Display the “GAP1 SENSOR
ADJUST” menu under “LABEL
SET” (Edit) mode.
In the fourth line on the LCD, the current
preset value (light quantity on the left,
threshold value on the right) will be
displayed.
2
Press the
key.
Move to selection of adjustment options and
the option line will be displayed in reverse
video.
3
Turn the dial to display a
random adjustment option.
Pitch Sensor
Content
AUTO
Automatically adjust pitch sensor.
Please read under mentioned “
Auto Adjustment of Pitch Sensor” for detailed
operational procedures.
MANUAL
Manually adjust pitch sensor.
Please read under mentioned “
Manual Adjustment of Pitch Sensor” for
detailed operational procedures.
Pressthe
key
and return to selection
of a setting menu.
Summary of Contents for DURA SI600
Page 1: ...THERMAL PRINTER INSTRUCTION MANUAL ...
Page 2: ......
Page 19: ...BEFORE OPERATION 1 3 Rear View ...
Page 20: ...BEFORE OPERATION 1 4 Operating Panel ...
Page 36: ...BEFORE OPERATION 1 20 ...
Page 48: ...BASIC OPERATIONS 2 12 ...
Page 54: ...SETUP PROCEDURE 3 6 3 1 3 Menu Flow of Setting Mode ...
Page 166: ...INSTALLING AND REMOVING THE OPTIONAL UNIT 5 12 ...
Page 167: ...INSTALLING AND REMOVING THE OPTIONAL UNIT 5 13 ...
Page 174: ......
Page 175: ...P N A2302B SECOND VERSION ...