SETUP PROCEDURE
3-19
3.3.6
Setting of Home Position
Set the Home Position of Pitch Sensor (Label Sensor).
1
Display the “HOME POSITION”
menu under “LABEL SET” (Edit)
mode.
The current preset value will be displayed
in the fourth line on the LCD.
2
Press the
key.
Move to the operation of setting Home
Position and the value line will be displayed
in reverse video.
3
Turn the dial to display the value
for setting.
Range for Setting : -50.000mm ~ 50.000mm
Adjustment Interval : 0.042mm
4
Press the
key.
Confirm the home position to return to the setting menu of operation selection and 1 piece of label
will be printed for test.
Pressthe
key
and return to selection
of a setting menu.