![Neve GENESYS BLACK User Manual Download Page 93](http://html1.mh-extra.com/html/neve/genesys-black/genesys-black_user-manual_1676765093.webp)
MASTER METER Section
The selection of the Metering buttons is remembered and reinstated each
time on boot-up
DAW
Lights when the 8T meters are being fed from the DAW metering. The
button itself has no intrinsic function and is for display only.
SOLO
This button will flash whenever a Solo (either
AFL
or
PFL
) is detected
anywhere on the console.
This display is for indication only.
USB
USB port for a flash drive so data can be quickly backed up or restored.
Talkback Mic
The Talkback Mic is situated on the Meterbridge for optimum acoustic
isolation.
The Metering Options buttons apply their functions globally across all
metering on the console:
VU
Sets all meter information to display in VU, and uses the scale to the left
of each meter.
PPM
Sets all meter information to display in PPM, and uses the scale to the
right of each meter.
VU
and
PPM
are interlocked.
SET
It is possible to alter the meter scaling in PPM mode.
u
Press
SET
.
The right-side of the 2T meter will now display a solid block of leds.
For each press of the PPM button, the scaling indicated by bright-up will
be:
•
+14dB
•
+18dB
•
+20dB
This will set the PPM bright-up to be one bar below +14, +18, +20 to
indicate near converter clipping.
Press
SET
again to exit this setup mode.
- 93 -