![Neve GENESYS BLACK User Manual Download Page 133](http://html1.mh-extra.com/html/neve/genesys-black/genesys-black_user-manual_1676765133.webp)
Connectors & switches
25-way D-type connectors
There are two 25-way D-type connectors on both the Master and Slave
FireWire cards.
These connectors use standard Tascam AES wiring protocol.
On a Master AD/DA card, from left to right, these D-type connectors are
labelled as follows:
1. AES RX DLINE / AES TX
2. AES RX DMON / AES Sync In/Out
Each 25-way connector carries (up to) 8 pairs signals, and these are as
follows:
AES RX DLINE / AES TX
Connector
number
Signal name
(system name)
Pin
Shield
Hi
Low
1
AES RX 1 (DLINE 1 & 2)
25
24
12
2
AES RX 2 (DLINE 3 & 4)
11
10
23
3
AES RX 3 (DLINE 5 & 6)
22
21
9
4
AES RX 4 (DLINE 7 & 8)
8
7
20
5
AES TX 1 (Direct Output 1 & 2)
19
18
6
6
AES TX 2 ( Direct Output 3 & 4 )
5
4
17
7
AES TX 3 ( Direct Output 5 & 6)
16
15
3
8
AES TX 4 ( Direct Output 7 & 8)
2
1
14
AES RX DMON / AES SYNC IN/OUT
Connector
number
Signal name
Pin
Shield
Hi
Low
1
AES RX 1 (DMON 1 & 2)
25
24
12
2
AES RX 2 (DMON 3 & 4)
11
10
23
3
AES RX 3 (DMON 5 & 6)
22
21
9
4
AES RX 4 (DMON 7 & 8)
8
7
20
5
-
-
-
-
6
-
-
-
-
7
AES Sync Out
*
16
15
3
8
AES Sync In
*
2
1
14
*
These are
AES Sync I/O
connections only, not audio paths.
Channel Slave Audio Link
These should only ever be connected to the corresponding port of the
same name on the associated Slave card,
1
to
1
,
2
to
2
and
3
to
3
.
Please see section on Cabling starting on page 146.
- 133 -