May 30, 2003 Beta Draft
GMRP Admin Mode
This displays the administrative mode of GARP Multicast Regis-
tration Protocol (GMRP) for the system.
GVRP Admin Mode
This displays the administrative mode of GARP VLAN Registra-
tion Protocol (GVRP) for the system.
show garp interface
This command displays Generic Attributes Registration Protocol (GARP) information for one or
all interfaces.
Format
show garp interface <slot.port/all>
Interface
This displays the slot.port of the interface that this row in the
table describes.
Join Timer
Specifies the interval between the transmission of GARP PDUs
registering (or re-registering) membership for an attribute. Cur-
rent attributes are a VLAN or multicast group. There is an
instance of this timer on a per-Port, per-GARP participant basis.
Permissible values are 10 to 100 centiseconds (0.1 to 1.0 sec-
onds). The factory default is 20 centiseconds (0.2 seconds). The
finest granularity of specification is 1 centisecond (0.01 seconds).
Leave Timer
Specifies the period of time to wait after receiving an unregis-
tered request for an attribute before deleting the attribute. Current
attributes are a VLAN or multicast group. This may be consid-
ered a buffer time for another station to assert registration for the
same attribute in order to maintain uninterrupted service. There is
an instance of this timer on a per-Port, per-GARP participant
basis. Permissible values are 20 to 600 centiseconds (0.2 to 6.0
seconds). The factory default is 60 centiseconds (0.6 seconds).
The finest granularity of specification is 1 centisecond (0.01 sec-
onds).
LeaveAll Timer
This Leave All Time controls how frequently LeaveAll PDUs are
generated. A LeaveAll PDU indicates that all registrations will
shortly be deregistered. Participants will need to rejoin in order to
maintain registration. There is an instance of this timer on a per-
Port, per-GARP participant basis. The Leave All Period Timer is
set to a random value in the range of LeaveAllTime to
1.5*LeaveAllTime. Permissible values are 200 to 6000 centisec-
onds (2 to 60 seconds). The factory default is 1000 centiseconds
(10 seconds). The finest granularity of specification is 1 centisec-
ond (0.01 seconds).