– 304 –
NWA-008841-001 Rev.5.0
90ch3002.fm
Switch Settings
The figure in the SWITCH NAME column and the position of
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
NOTE 1
0-3
For setting FP No.
0
Not used
1
For mounting this card in PIM2
2
For mounting this card in PIM4
3
For mounting this card in PIM6
4-F
Not used
MB (Toggle SW)
NOTE 2
UP
For make-busy
For normal operation
SW1
(Piano Key SW)
1-3
Not used
4
For normal operation
OFF
Not used
0
1
2
3
ON
DOWN
4
3
2
1
OFF
ON
OFF
ON
PN-CP15 (FP)