– 474 –
NWA-008841-001 Rev.5.0
90ch3003.fm
Switch Settings
The figure in the SWITCH NAME column and the position of
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
NOTE 3:
When the U-interface CS (ZT) is used, one CSH card per system must be set to the SW1-1 switch
ON. And mount the CSH card which SW1-1 is set to ON into PIM0.
NOTE 4:
When the S-interface CS (ZT) is used, set the SW1-1 switch to OFF.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
NOTE 1
4-F
Set the switch to match the AP Number (04-31) to be
set by CM05.
0-3
Not used
MB (Toggle SW)
NOTE 2
UP
For make-busy
For normal operation
SW1
(Piano SW)
1
NOTE 3
NOTE 4
ON
60 ms synchronization clock ON
OFF
60 ms synchronization clock OFF
2
Not used
3
Not used
4
ON
AP No. 04-15
OFF
AP No. 20-31
F
4
AP No.
SW1-4: ON
04 05 06 07 08 09 10 11 12 13 14 15
SW1-4: OFF
20 21 22 23 24 25 26 27 28 29 30 31
SW No.
4
5
6
7
8
9
A
B
C
D
E
F
ON
DOWN
4
3
2
1
OFF
ON
OFF
OFF
JULY/1/2006
PN-SC03-B/PN-SC03-C (CSH)