– 383 –
NWA-008841-001 Rev.5.0
90ch3003.fm
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SW2 (Dip SW)
1
ON
Control channel signaling data trans-
mission speed: 48 Kbps
Control channel signaling data trans-
mission speed: 64 Kbps
2
ON
DTI frame configuration: 12-Multi
Frame
DTI frame configuration: 24-Multi
Frame
3
ON
Line code: AMI with ZCS
Line code: B8ZS
4
ON
Setting of control signal time slot
NOTE 2:
The time slot number 0, 20,
21, and 22 (TS0/20/21/22)
cannot be used for control
signal.
NOTE 3:
This setting must be identical
with the opposite DAIA card.
5
ON
6
ON
7
OFF
8
ON
Continued on next page
1 2 3 4 5 6 7 8
ON
OFF
OFF
OFF
SWITCH NUMBER
TIME SLOT
NUMBER
4
5
6
7
8
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
TS1
TS2
TS3
TS4
TS5
TS6
TS7
TS8
TS9
TS10
TS11
TS12
TS13
TS14
TS15
TS16
TS17
TS18
TS19
TS23
OFF
OFF
OFF
ON
OFF
PN-DAIB (DAIB)