• This figure shows MDF cross connection for No. 0 circuit on the PZ-8PFTB.
MDF Cross Connection for PFT
Continued on next page
50
TO STATION
27
2
33
8
26
1
27
2
26
1
33
8
J
P
PIM0
LT00
35
41
34
9
35
34
9
41
T1
LEN009
(No. 1)
R1
T0
LEN008
(No. 0)
R0
T7
LEN015
(No. 7)
R7
PN-8COT
LT01
T1
LEN001
(No. 1)
R1
T0
LEN000
(No. 0)
R0
T7
LEN007
(No. 7)
R7
PN-8LC
PZ-PW121/PZ-PW126
–27 V
G
26
1
Sta. R0
Sta. T0
28
3
C.O. R0
C.O. T0
29
4
8COT. R0
8COT. T0
27
2
8LC. R0
8LC. T0
PFT0
TO C.O. LINE
PZ-8PFTB
No. 0
P
J
PFT1
49
24
50
25
–27 V
E
P
J
Tip
Ring
Tip
Ring
MDF
INSTALLATION CABLE
LTC0
10
10
16
16
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PN-CP24-A/CP24-B/
50
MN
MJ
25
25
48
23
MJ
•
•
•
•
•
•
CP24-C/CP24-D
JULY/1/2006
Power Failure Transfer (PFT)