![background image](http://html.mh-extra.com/html/nec/univerge-neax-2000-ips/univerge-neax-2000-ips_installation-manual_251421411.webp)
– 395 –
NWA-008841-001 Rev.5.0
90ch3003.fm
Switch Settings
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
0-F
Always set to 0
1-F
Not used
MB (Toggle SW)
NOTE 1
UP
For make-busy
For normal operation
SW1
(Piano Key SW)
1
Always set to OFF
2
Always set to OFF
3
Always set to OFF
4
Always set to OFF
SW2 (Dip SW)
1
ON
Control channel signaling data trans-
mission speed: 48 Kbps
Control channel signaling data trans-
mission speed: 64 Kbps
2
ON
CRC Synchronization Detection Timer
is provided.
CRC Synchronization Detection Timer
is not provided.
3
ON
CRC4 Check is provided.
CRC4 Check is not provided.
Continued on next page
0
ON
DOWN
4
3
2
1
OFF
ON
OFF
OFF
OFF
OFF
1 2 3 4 5 6 7 8
ON
OFF
OFF
OFF
PN-DAIE (DAIE)