![background image](http://html.mh-extra.com/html/nec/univerge-neax-2000-ips/univerge-neax-2000-ips_installation-manual_251421068.webp)
CHAPTER 1 GENERAL INFORMATION
– 52 –
NWA-008841-001 Rev.5.0
90ch1001.fm
(4) Mounting Conditions of Each Card
CARD NAME
MOUNTING CONDITIONS
PN-PW00
No circuit card can be mounted in the adjoining left side slot because
one card occupies two physical slots width.
PN-BRTA
PN-2BRTC
PN-2BRTK
PN-4BRTA-A
PN-24CCTA
PN-30CCTA
PN-24DTA-C
PN-30DTC-C
PN-24PRTA
PN-30PRTA
PN-DTA
PN-DTB
Mount at least one card in PIM0 to receive source clock signals.
PZ-M542
PZ-M557
Mount the PZ-M542/PZ-M557 card into any LTC connector of PIM
BWB.
Maximum of two cards can be mounted per PIM as follows:
LTC0 and LTC2
LTC0 and LTC3
LTC1 and LTC3
PN-4BRTA-A
Maximum of six cards can be mounted per PIM, maximum of 24 cards
per system. For the same number of slots as PN-4BRTA-A cards, only
line/trunk cards can be mounted in any slot of LT00-LT11 slots of each
PIM.
PN-8ETIA
[For North America/
Australia]
No circuit card can be mounted in the adjoining left side slot because
one card occupies two physical slots width.
JULY/15/2007
MOUNTING CONDITIONS OF CIRCUIT CARDS