CHAPTER 2 INSTALLATION
– 102 –
NWA-008841-001 Rev.5.0
90ch2001.fm
• Hanging PIM to HANGER ASSEM
(1) Secure the HANGER ASSEM to the surface of a wall with three screws.
Select screws to match with the wall type as follows.
A concrete wall is recommended because it is the most firm to mount the PBX of the three. The
plaster board is the most infirm wall of the three.
(2) Hang the slits of the rear of a PIM to the hooks of the HANGER ASSEM.
(3) Secure the PIM to the HANGER ASSEM with two screws.
NOTE:
Screws are attached to the HANGER ASSEM.
Hanging PIM to HANGER ASSEM
WALL TYPE
RECOMMENDED SCREW
CONCRETE
ANCHOR BOLT TYPE
Recommended 4 mm (0.16 inch)
by 25 mm (0.98 inch)
WOOD
WOOD TYPE SCREWS
Minimum 3.5 mm (0.14 inch) DIA
Maximum 4.5 mm (0.17 inch) DIA
PLASTER BOARD
[THICKNESS Minimum 9.6 mm (0.38 inch)]
MOLLY ANCHOR TYPE Minimum 3.5 mm (0.14 inch) DIA
Maximum 4.5 mm (0.17 inch) DIA
HOOK
HOOK
HANGER ASSEM
PIM
BASE
SCREWS