![background image](http://html.mh-extra.com/html/nec/univerge-neax-2000-ips/univerge-neax-2000-ips_installation-manual_251421413.webp)
– 397 –
NWA-008841-001 Rev.5.0
90ch3003.fm
The figure in the SWITCH NAME column and the position of
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
NOTE 1:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
SW3 (Dip SW)
1
Always set to ON
2
Always set to ON
3
Always set to ON
4
Always set to OFF
JPS (Jumper pin)
Balanced transmission: 120
Ω
(For
twisted-pair cable)
LEFT
TA is grounded on the transmission
line: 75
Ω
(For coaxial cable)
JPR (Jumper pin)
RIGHT
RA is grounded on the transmission
line: 75
Ω
(For coaxial cable)
Balanced transmission: 120
Ω
(For
twisted-pair cable)
E1Z (Jumper pin)
RIGHT
Line impedance: 75
Ω
(For coaxial
cable)
Line impedance:
120
Ω
(For twisted-pair cable)
SRT (Jumper pin)
RIGHT
Line impedance:
75
Ω
(For coaxial cable)
Line impedance:
120
Ω
(For twisted-pair cable)
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4
ON
ON
ON
ON
OFF
RIGHT
LEFT
LEFT
LEFT
PN-DAIE (DAIE)