– 543 –
NWA-008841-001 Rev.5.0
90ch3004.fm
Switch Settings
• PN-32IPLA-A
NOTE:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
MB (Toggle SW)
NOTE
UP
For make-busy
For normal operation
SW0
(Piano Key SW)
1
Not used
2
Not used
3
Not used
4
Not used
DOWN
4
3
2
1
OFF
ON
OFF
OFF
OFF
OFF
PN-32IPLA-A (IP-PAD)