CHAPTER 1 GENERAL INFORMATION
– 37 –
NWA-008841-001 Rev.5.0
90ch1001.fm
Line/Trunk Card Name and Function
Continued on next page
EQUIPMENT
NAME
FUNCTIONAL
NAME
FUNCTION
PN-8LCAK
LC
8-line Analog Line Circuit Card for Single Line Telephones
Loop resistance : Maximum 600
Ω
(including telephone set)
Provides Message Waiting Lamp control, momentary open, Line
Test functions for each circuit.
[Series 3800 software (ver.3.0) or later required]
PN-2LDTA
LDT
2-line Loop Dial Trunk Card
Loop resistance : Maximum 2500
Ω
(including internal resistance
of the distant office equipment)
Equipped with –48 V DC-DC on-board power supply.
PN-4LDTA
LDT
4-line Loop Dial Trunk Card
Loop resistance : Maximum 3000
Ω
(including internal resistance
of the distant office equipment)
PZ-PW122 is required.
PN-4LLCB
LLC
4-line Analog Long Line Circuit Card for Single Line Telephones
Provides Caller ID Display on analog station.
Loop resistance for PB/DP type:
PB :
Maximum 1200
Ω
DP (20 PPS) : Maximum 1700
Ω
DP (10 PPS) : Maximum 2500
Ω
Including the internal resistance of the distant office equipment
Provides Message Waiting Lamp control, momentary open/
reverse functions for each circuit.
PZ-PW122 is required.
PN-M10
M10
Optical Fiber Interface Card
Provides optical fiber interface for T1/E1 Digital Trunk Interface
(1.5 M/2 Mbps) or Remote PIM.
Line length : 10 km (6.2 miles) or less
Line coding : CMI
PN-M13
M13
24-line Plain Old Telephone Service (POTS) Splitter Card
Used to provide data communications for HomePNA (Phoneline Net-
work Alliance)/VDSL (Very-high-data-rate Digital Subscriber Line).
PN-2ODTA
ODT
2-line Out Band Dialing Trunk Card
Used as either a 2-wire E&M trunk or a 4-wire E&M trunk.
Equipped with –48 V DC-DC on-board power supply.
Both No. 0 and No. 1 circuits must be set to the same purpose (2-
wire or 4-wire) in one card.
JANUARY/26/2007
EQUIPMENT NAME AND FUNCTION