![background image](http://html.mh-extra.com/html/nec/univerge-neax-2000-ips/univerge-neax-2000-ips_installation-manual_251421075.webp)
CHAPTER 1 GENERAL INFORMATION
– 59 –
NWA-008841-001 Rev.5.0
90ch1001.fm
NOTE 2:
The maximum DC power output of PZ-PW122 (DC/DC PWR) card is 1.7 A.
When LT card (PN-4CSIA/PN-4CSIA-A/PN-4DLCT/PN-4LDTA/PN-4LLCB/PN-4ODTA*
card) that require the PZ-PW122 card is mounted, the sum current from each card to terminals
should be set to less than 1.7 A.
PN-4CSIA/PN-4CSIA-A/PN-4DLCT/PN-4LDTA/PN-4LLCB/PN-4ODTA card should be
mounted in the same PIM which accommodates PZ-PW122.
*
When using the signaling type I.
Card
Current
(1 card)
The maximum
accommodation
number of cards
(1 PIM)
Accommodation
conditions
(1 PIM)
(1) PN-4CSIA/
PN-4CSIA-A
400 mA
4
(1) + (2) + (3) + (4) + (5)
≤
1.7 A
(2) PN-4DLCT
180 mA
9
(3) PN-4LDTA
140 mA
12
(4) PN-4LLCB
140 mA
12
(5) PN-4ODTA*
500 mA
3
NOVEMBER/15/2006
MOUNTING CONDITIONS OF CIRCUIT CARDS