![background image](http://html.mh-extra.com/html/nec/univerge-neax-2000-ips/univerge-neax-2000-ips_installation-manual_251421046.webp)
CHAPTER 1 GENERAL INFORMATION
– 30 –
NWA-008841-001 Rev.5.0
90ch1001.fm
Line/Trunk Card
This table shows the names and functions of each line/trunk card.
Line/Trunk Card Name and Function
Continued on next page
EQUIPMENT
NAME
FUNCTIONAL
NAME
FUNCTION
PN-2AMPA
AMP
2-line Amplifier Trunk Card
Provides Echo Canceller (EC), Automatic Gain Controller (AGC)
and Tone Disabler (TD) functions.
PN-CFTA
CFT
6/10 Party Conference Trunk Card
Use of one card: Can control a conference of up to six partici-
pants.
Use of two cards: Can control a conference of up to ten partici-
pants.
PN-CFTB
CFT
6/10 Party Conference Trunk Card
Use of one card: Can control a conference of up to six partici-
pants.
Use of two cards: Can control a conference of up to ten partici-
pants.
PN-2COTD
COT
2-line Central Office Trunk Card (Loop Start Trunk)
Provides metering pulse detection function.
PN-2COTE
[For
Australia/
Asia/
Middle East]
COT
2-line Central Office Trunk Card (Loop Start Trunk)
Provides metering pulse detection function.
PN-4COTA-A
COT
4-line Central Office Trunk Card (Loop Start Trunk)
Provides a detector for line fault conditions.
PN-4COTB
COT
4-line Central Office Trunk Card (Loop Start/Ground Start Trunk)
Provides loop detection, sending/detecting ground on Tip/Ring
wire.
PN-4COTE
[For
Australia]
COT
4-line Central Office Trunk Card (Loop Start Trunk)
Provides a detector for line fault conditions.
OCTOBER/31/2005
EQUIPMENT NAME AND FUNCTION