MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
LED Fault Indications
Table 13-1
Site Controller LED Fault Indications (Continued)
Indication
Possible Failure
Corrective Action
code, or reset unit
- If problem still exists replace faulty unit
with new one
BR con
fi
gured loss:
- Check state of BRs (br con
fi
gured is missing)
status sc -all
,
status br
*) Canbus commands
BR1 or BR2 or BR3 or
BR4 or Service LED: OFF
Ethernet link not present
- Check if Ethernet cable is connected
- If still no LED indication, replace the cable
E1 LEDs: Amber
Errors FE, CRC, BPV, PD
- Verify the cabling
- Check if the cable is plugged to right
connector
- Replace E1 cable if no change
-
status bsl
E1 LEDs: RED
Primary E1 failure LOS,
Link down
- Verify the cabling
- If no change replace E1 cable
Figure 13-1
Site Controller LEDs
6802800U74-N September 2009
13-3