MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
Determining Power Connection Wire Size
Procedure 4-6
How to Connect –48 VDC Power Source to Equipment Cabinet (Continued)
5
Connect the other end of wires to -48 VDC output in accordance with manufacturer’s instructions
and any applicable local regulations.
6
The MTS DC plug shall be
fi
xed to the DC connector using the plug’s screws.
Determining Power Connection Wire Size
Wire size recommendations contained herein reflect Motorola engineering
requirements
for proper system operation. Local regulations shall be adhered to in any case and
shall supersede any other specifications in this manual, where applicable.
Wire used for DC connection shall not be smaller than 3.3 mm
2
(#12 AWG) or
greater than 5.3 mm
2
CSA (#10 AWG). Blue is the color recommended for -48
VDC wires. However, if the wire is not color-coded, mark these leads with a
colored tracer on each end. Wire used for AC connection shall not be smaller
than 1.3 mm
2
CSA (#16 AWG) or greater than 2.1 mm
2
(#14 AWG).
110 VAC – 240 VAC Input Power Connections
and
depicts the newer version of the MTS Junction Panel.
There may be small differences in older con
fi
gurations.
6802800U74-N September 2009
4-25
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...