MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
110 VAC – 240 VAC Input Power Connections
Figure 4-25
110-240 VAC Connections on the Expansion Cabinet Junction Panel
Make sure all power to the Power Supply Unit is switched off to prevent
accidental contact with high energy and injury to personnel.
Procedure 4-7
How to Connect 110 – 240 VAC Power Source to Equipment Cabinet.
1
Connect the AC cable to the AC socket (type IEC C15 line socket, Motorola P/N 3166502A01),
which is provided with the MTS.
2
Insert the AC socket into the AC input connector on the MTS and
fi
x with the retaining clip as
shown in
. This
fi
xture will only work with the supplied IEC connector.
6802800U74-N September 2009