MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
Base Radio Alarms
Table 13-7
Generic Base Radio Alarms (Continued)
Alarm ID
Description
Recovery
Action
Clear Action
Notes
ALM_EX_DC_12V_FAULT
Exciter DC 12V
line failure.
Transmitter is
disabled by
the software -
BRC is unable to
transmit.
If the alarm
condition
disappears then
transmitter is
re-enabled by the
software.
The alarm may be
reported because
of some power
supply problems
(cables, connectors)
or the BRC hardware
failure / con
fi
guration
problem.
ALM_EX_DC_5V_FAULT
Exciter DC 5V
line failure.
Transmitter is
disabled by
the software -
BRC is unable to
transmit.
If the alarm
condition
disappears then
transmitter is
re-enabled by the
software.
The alarm may be
reported because
of some power
supply problems
(cables, connectors)
or the BRC hardware
failure / con
fi
guration
problem.
ALM_EX_DC_2_775V_FAULT
Exciter DC
2.775V line
failure.
Transmitter is
disabled by
the software -
BRC is unable to
transmit.
If the alarm
condition
disappears then
transmitter is
re-enabled by the
software.
The alarm may be
reported because
of some power
supply problems
(cables, connectors)
or the BRC hardware
failure / con
fi
guration
problem.
ALM_EX_DC_3_3V_FAULT
Exciter DC 3.3V
line failure.
Transmitter is
disabled by
the software -
BRC is unable to
transmit.
If the alarm
condition
disappears then
transmitter is
re-enabled by the
software.
The alarm may be
reported because
of some power
supply problems
(cables, connectors)
or the BRC hardware
failure / con
fi
guration
problem.
ALM_EX_DC_1_875V_FAULT
Exciter DC
1.875V line
failure.
Transmitter is
disabled by
the software -
BRC is unable to
transmit.
If the alarm
condition
disappears then
transmitter is
re-enabled by the
software.
The alarm may be
reported because
of some power
supply problems
(cables, connectors)
or the BRC hardware
failure / con
fi
guration
problem.
6802800U74-N September 2009
13-39
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...