Chapter 15: Expansion Options
Configuration
Basic con
fi
guration of base radios is needed when additional base radio(s) has been added to the MTS
4 cabinet. This is described in
.
Base radios in the second Module Cage should be con
fi
gured with
cabi-
net:position
set as
1:3
and
1:4
.
For con
fi
gurations with Manual Tuned Cavity Combiner(s), the MTCC needs to
be tuned after adding additional Base Radio.
In addition to this, the following parameters need to be con
fi
gured in TESS application:
•
Factory password
•
Field password
•
Cabinet ID
•
Position ID
•
Carrier Number (TX/RX frequencies are auto-generated based on Carrier Number setting)
•
Default TX Power level
When these parameters have been con
fi
gured in TESS Application and after the
modi
fi
ed con
fi
guration
fi
le has been uploaded to the Site Controller, the complete site
needs to be reset to implement the con
fi
guration change.